Care and use guide
In just one glance the
Bluelab Guardian Monitor
magically measures all
3 critical parameters for
successful growth:
pH, conductivity AND
temperature
Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - Care and use guide

Care and use guideIn just one glance the Bluelab Guardian Monitor magically measures all 3 critical parameters for successful growth:pH, conductivity

Página 2 - page page

English1010.0 pH calibration cont.pH calibration LEDsThe LEDs next to the pH window will let you know thestatus of calibration. See the table below

Página 3 - Bluelab Guardian Monitor

English1112.0 Set alarms (optional)The alarm function warns you when the solutiondeviates from the desired levels you have chosenfor each measureme

Página 4 - 1.0 What’s in the box?

English1212.0 Set alarms (optional) cont.Turn alarm ON/OFFPress the alarm button to change between alarm ON and alarm OFF.When the alarm is ON the

Página 5

English1313.0 Cleaning the conductivity/temperature probeCleaning the Bluelab Conductivity/Temperature ProbeCleaning the conductivity/temperature pro

Página 6

English1414.0 Cleaning the Bluelab pH ProbeTo ensure accurate readings the pH probe tip needs to be rinsed in water after each use and cleaned prior

Página 7 - 6.0 Power up

English1516.0 Troubleshooting guideTrouble Reason CorrectionNutrient reading lowContaminated conductivity/temperature probe.Clean conductivity/tempe

Página 8 - 10.0 Calibration

English1617.0 Technical speci cationsSpecifi cations pH Conductivity TemperatureRange0.0 – 14.0 pH0 – 5.0 EC,0 – 50 CF, 0 – 2500 TDS (ECx500),0 – 35

Página 9

English17pH probes do not last forever. They agethrough normal use and will eventually fail.To ensure you receive a long life from your pHprobe, pleas

Página 10 - 11.0 Placement of probes

English18If you need assistance or advice - we’re here to help you.Phone: +64 7 578 0849 Fax: +64 7 578 0847Email: [email protected]

Página 11 - 12.0 Set alarms (optional)

English2Features 3Bluelab Guardian Monitor 3What’s in the box? 4IMPORTANT - Bluelab pHProbe care 5Mounting the Bluelab Guardian Monitor - if wall m

Página 12

English3Features‘Plant Safe’ green LED display Visual alarm for both high and low settingsLarge easy to read displaysGreater tolerance to RF/electroni

Página 13

English4PLEASE FOLLOW THE MANUAL STEP BY STEP BEFORE FIRST USE BEGINS1.0 What’s in the box?Please verify the box contents from the information below

Página 14 - 15.0 Hydrating the pH probe

English52.0 IMPORTANT - Bluelab pH Probe careThe Bluelab pH Probe is the only part of the Bluelab Guardian Monitor that should ever require replacing

Página 15 - 16.0 Troubleshooting guide

English63.0 Mounting the Bluelab Guardian Monitor - if wall mountingSelect a suitable location that is less than 2 meters from your reservo

Página 16

English76.0 Power upSwitch on power adaptor at the mains.When power is applied the Guardian Monitor will complete a display test sequence.127.0

Página 17 - Solution

English8English10.0 CalibrationpH calibration is required before fi rst use to ensure that the fi rst reading is accurate.• The Bluelab Conductivity

Página 18 - Limitation of Liability

English910.0 pH calibration cont.To calibrate the pHClean pH probe tip.See section 14.0 (the pH probe does not require cleaning before the fi rst us